InstallatIon GuIdeXR500 seRIes Command PRoCessoR™ Panel
Digital Monitoring Products XR500 Series Installation Guide2IntRoduCtIonPanel Features2.1 DescriptionTheDMPXR500SeriesCommandProcessor™Paneli
XR500 Series Installation Guide Digital Monitoring Products3IntRoduCtIon2.5 Encrypted Communications (XR500N/XR500E only)An XR500E panel communicate
Digital Monitoring Products XR500 Series Installation Guide4IntRoduCtIon3.2 Wiring DiagramThe XR500 Series diagram below shows some of the accessory
XR500 Series Installation Guide Digital Monitoring Products5IntRoduCtIon3.3 Lightning ProtectionMetal Oxide Varistors and Transient Voltage Suppress
Digital Monitoring Products XR500 Series Installation Guide6IntRoduCtIon3.4 Accessory Devices (continued)DMP Two-Way Wireless Devices (continued)* 1
XR500 Series Installation Guide Digital Monitoring Products7InstallatIonInstallation4.1 Mounting the EnclosureThe metal enclosure for the XR500 Seri
Digital Monitoring Products XR500 Series Installation Guide8InstallatIon5 4 3 2 19 8 7 6GRS232J1E
XR500 Series Installation Guide Digital Monitoring Products9InstallatIon4.3 Connecting LX-Bus and Keypad Bus DevicesSeveral factors determine the DM
Digital Monitoring Products XR500 Series Installation Guide10InstallatIonSecondary Power Supply6.1 Battery Terminals 3 and 4Connect the black batter
XR500 Series Installation Guide Digital Monitoring Products11InstallatIon6.8 XR500 Series Power RequirementsDuring AC power failure, the XR500 Serie
MODEL XR500, XR500N, XR500ECOMMAND PROCESSORINSTALLATION GUIDE FCC NOTICEThis equipment generates and uses radio frequency energy and, if not install
Digital Monitoring Products XR500 Series Installation Guide12InstallatIonStandby Battery Power Calculations Standby Current Alarm Current736P POPIT I
XR500 Series Installation Guide Digital Monitoring Products13InstallatIon6.9 Standby Battery SelectionTo choose the type and number of batteries nee
Digital Monitoring Products XR500 Series Installation Guide14InstallatIonBell Output7.1 Terminals 5 and 6Terminal 5 supplies positive 12 VDC to powe
XR500 Series Installation Guide Digital Monitoring Products15InstallatIonProtection Zones10.1 Terminals 13–24Zones1to8(terminals13to24)onth
Digital Monitoring Products XR500 Series Installation Guide16InstallatIon11.2 Compatible 2-Wire Smoke Detector ChartManufacturer Model Detector IDBa
XR500 Series Installation Guide Digital Monitoring Products17InstallatIonDry Contact Relay Outputs12.1 DescriptionThe XR500 Series panel provides tw
Digital Monitoring Products XR500 Series Installation Guide18InstallatIonJ23 6-Pin Header14.1 DescriptionThe XR500 Series Command Processor™ panel s
XR500 Series Installation Guide Digital Monitoring Products19InstallatIon15.3 LX-Bus Interface CardsYou can add one Interface Card (Model 481, 462N,
Digital Monitoring Products XR500 Series Installation Guide20InstallatIon16.3 Direct iCOM Connection to J21Use DMP Model 397 cable with a DB-9 femal
XR500 Series Installation Guide Digital Monitoring Products21InstallatIon18.2 DescriptionConnect the panel to the public telephone network by instal
XR500 Series Installation Guide Digital Monitoring Productsitable of ContentsProduct Specications1.1 Power Supply ...
Digital Monitoring Products XR500 Series Installation Guide22InstallatIonReset and Tamper Headers19.1 J16 Reset Header The reset header is located j
XR500 Series Installation Guide Digital Monitoring Products23ComPlIanCeUniversal Burglary Specications20.1 IntroductionTheprogrammingandinstal
Digital Monitoring Products XR500 Series Installation Guide24ComPlIanCeArea Information21.1 OwnershipThe control unit system shall be under one owne
XR500 Series Installation Guide Digital Monitoring Products25ComPlIanCeANSI/UL 1610 AND ANSI/UL 1076 SpecicationsCentral-Station and Proprietary Bur
Digital Monitoring Products XR500 Series Installation Guide26ComplianCe23.11 Model 463G CELL with Dialer Backup, Standard or Encrypted Line Security
XR500 Series Installation Guide Digital Monitoring Products27ComPlIanCeANSI/UL 636 SpecicationsHoldup Alarm Units24.1 ANSI/UL 1610 RequiredTheprog
Digital Monitoring Products XR500 Series Installation Guide28ComPlIanCe26.2 Entry DelayThe maximum entry delay used must not be more than 60 seconds
XR500 Series Installation Guide Digital Monitoring Products29ComPlIanCe26.12 Model 463G NET with CELL as Alternate Primary and Dialer Backup, Standa
Digital Monitoring Products XR500 Series Installation Guide30ComPlIanCe27.4 Mercantile Safe and VaultWhen the DMP Model 350A housing is used, the XR
XR500 Series Installation Guide Digital Monitoring Products31ComPlIanCe29.3 TransformerA wire-in trans former should be used. Use the Model 322 wir
Digital Monitoring Products XR500 Series Installation Guideiitable of ContentsSmoke and Glassbreak Detector Output9.1 Terminals 11 and 12 ...
Digital Monitoring Products XR500 Series Installation Guide32ComPlIanCe30.3 Sprinkler SupervisoryAnyzoneusedforsprinklersupervisorymustbepro
XR500 Series Installation Guide Digital Monitoring Products33ComPlIanCe31.5 Detect Wireless JammingTheDetectWirelessJammingoptionmustbeprogra
Digital Monitoring Products XR500 Series Installation Guide34WIRInG dIaGRamsFalse Alarm Reduction Programmable Options *34.1 Shipping Defaults and R
XR500 Series Installation Guide Digital Monitoring Products35WIRInG dIaGRamsFalse Alarm Reduction Programmable Options (continued)34.2 Call Waiting
Digital Monitoring Products XR500 Series Installation Guide36WIRInG dIaGRamsWiring Diagrams36.1 Multiple Notication Circuit ModulesAC12345678 10 11
XR500 Series Installation Guide Digital Monitoring Products37WIRInG dIaGRams36.2 Multiple Notication Circuit Modules for Zoned AnnunciationAC123456
Digital Monitoring Products XR500 Series Installation Guide38WIRInG dIaGRams36.3 Dual Style D Zone Module InstallationJ6 Interface Card Expansion Co
XR500 Series Installation Guide Digital Monitoring Products39WIRInG dIaGRams36.4 Cellular Backup Installation for Derived Channel BurglaryJ6 Interfa
Digital Monitoring Products XR500 Series Installation Guide40WIRInG dIaGRams36.5 Derived Channel Installation Using Bosch D8122J6 Interface Card Exp
XR500 Series Installation Guide Digital Monitoring Products41WIRInG dIaGRams36.6 Rothenbuhler 5110 High Security Bell WiringJ6 Interface Card Expans
XR500 Series Installation Guide Digital Monitoring Productsiiitable of Contents20.7 Listed Receivers...
Digital Monitoring Products XR500 Series Installation Guide42WIRInG dIaGRams36.7 LX-Bus™ Module Connection+-Model 716 Output Expander Module 7m at 1
XR500 Series Installation Guide Digital Monitoring Products43WIRInG dIaGRams36.8 Model 860 Relay Module ConnectionJ6 Interface Card Expansion Connec
Digital Monitoring Products XR500 Series Installation Guide44WIRInG dIaGRams36.9 Powered Burglary DevicesJ6 Interface Card Expansion ConnectorXR500
XR500 Series Installation Guide Digital Monitoring Products45RevIsIonsRevisions to This DocumentThis section explains the changes that were made to t
LT-0681 1.03 © 2008 Digital Monitoring Products, Inc.800-641-4282www.dmp.comMade in the USAINTRUSION•FIRE•ACCESS•NETWORKS2500 North Partnership
Digital Monitoring Products XR500 Series Installation Guideivtable of ContentsANSI/UL 365 Specications26.1 System Trouble Display ...
XR500 Series Installation Guide Digital Monitoring Productsvtable of ContentsANSI/UL 985 NFPA 72 (Chapter 2) Specications31.1 Bell Output Denitio
XR500 Series Installation Guide Digital Monitoring Products1IntRoduCtIonProduct Specications1.1 Power SupplyTransformer Input: Model 327, plug-in
Commenti su questo manuale