Digital Monitoring Products XRSuper6/XR20/XR40 Installation Guide
20
ComplIanCe
False Alarm Reduction Programmable Options *
25.1 Shipping Defaults and Recommended Programming for ANSI/SIA CP-01-2000
SIA CP-01 FEATURE
PARAGRAPH # AND
DESCRIPTION
DMP PROGRAMMING
GUIDE LT-0305
SECTION #
REQUIREMENT RANGE
SHIPPING
DEFAULT
RECOMMENDED
PROGRAMMING*
4.2.2.1 Exit Time 6.6 Exit Delay
Required
(Programmable)
45 sec. - 250 sec.
60
Seconds
60 Seconds
4.2.2.2 Progress
Annunciation
9.12 Prewarn Address
(XR40 only)
Allowed
Individual keypads
may be disabled per
zone
All
keypads
enabled
All keypads enabled
4.2.2.3 Exit Time
Restart
6.6 Exit Delay Required Option
For re-entry during
exit time
Enabled Enabled
4.2.2.5 Auto Stay Arm
on Unvacated Premises
23.3 Occupied
Premise -
See Install
Guide (LT-0624)
Required Option
(except for
remote arming)
Area 1 = Perimeter
Area 2 = Interior
Enabled
Enabled for
Residential
Applications
4.2.4.4 Exit Time and
Progress Annunciation/
Disable - for Remote
Arm
Not Available on
Remote Arming
Allowed Option
Progress Annunciation
Always disabled for
Remote Arming
Not
Available
Remote Arming not
allowed for CP-01
installations.
4.2.3.1 Entry Delay(s) 6.5 Entry Delay
Required
(Programmable)
30 sec. – 240 Sec. **
30
Seconds
At least 30 Seconds **
4.2.5.1 Abort Window –
for Non-Fire Zones
3.4 Transmit Delay Required Option
Disable by zone or
zone type
Enabled
NT DY
EX Zone
Enabled
4.2.5.1 Abort Window
Time – for Non-Fire
Zones
3.4 Transmit Delay
Required
(Programmable)
20 sec., 30 sec., or
40 sec. **
30
Seconds
At least 20 Seconds **
4.2.5.1.2 Abort
Annunciation
3.4 Transmit Delay Required Option
Annunciate that
no alarm was
transmitted
Yes Yes
4.2.5.4.1 Cancel
Annunciation
Always Enabled - Not
Programmable
Required Option
Annunciate that
a Cancel was
transmitted (S49)
Always
Enabled
Yes
4.2.6.1 & 4.2.6.2
Duress Feature
User Code + 1 =
Ambush Code Not
Available
Allowed Option
No 1 + derivative of
another user code/no
duplicates with other
user codes
Code +1
Always
Disabled
Not Programmable
4.3.1 Cross Zoning 9.14 Cross Zone Required Option
Yes/No Zone
Programming
No
Enabled using two or
more programmed
zones
4.3.1 Programmable
Cross Zoning Time
6.7 Cross Zone Time Allowed 4 sec. - 250 sec. 4 Seconds
Per walk path in
protected premises
4.3.2 Swinger Shutdown
Not Available —
Always On
Required
For all non-re
zones, shut down
after 1 trip
Always
On
Always On
4.3.2 Swinger Shutdown
Disable
9.11 Swinger Bypass Allowed
For non-police
response zones
Yes Enabled (all zones)
4.3.3 Fire Alarm
Verication
9.4 Zone Type Required Option FV Type Zone No
Yes as required
(unless sensors can
self verify)
4.5 Call Waiting Cancel
3.16 Telephone
Number
Required Option
Include *70P in
Telephone Number
Disabled
Enabled if user has
call waiting
* Programming at installation may be subordinate to other UL requirements for the intended application.
** For UL Installations, combined Entry Delay and Transmit Delay should not exceed 1 minute.