Digital Monitoring Products XR550 Manuale delle Istruzioni Pagina 12

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 78
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 11
Digital Monitoring Products XR150/XR350/XR550 Series Programming Guide
2
INTRODUCTION
1.3 Encrypted Communications (XR550 with Encryption only)
Some installations require secure data communications. Use a unique passphrase to enable encrypted
communications and provide a secure means for data communications. See Network Options.
An XR550 panel with encryption communicates using 128-bit or 256-bit AES encryption. If you currently have
an XR550 panel with network installed, you may purchase a separate feature key to activate encrypted
communications using the Feature Upgrade process. Encrypted communication cannot be enabled on a standard
XR550 panel. For more information on the Feature Upgrade process see Section 21 in this document.
1.4 Programmer Operation
There are 20 programming sections to choose from:
Programming Item Section in This Manual Programming Item Section in This Manual
Initialization 2 Output Information 12
Communication 3 Output Groups 13
Network Options 4 Menu Display 14
Messaging Setup 5 Status List 15
Device Setup 6 PC Log Reports 16
Remote Options 7 Area Information 17
System Reports 8 Zone Information 18
System Options 9 Stop 19
Bell Options 10 Set Lockout Code 20
Output Options 11
To choose a section for programming, press any top row Select key when the keypad displays the name of that
section. Sections 2 through 20. contain detailed instructions for each programming step.
1.5 Programmer Lockout Codes
The panel allows you to enter the programming function without entering a lockout code using steps 1 to 4 listed
in Getting Started. We recommend, however, that you install a Lockout Code to restrict programming to only those
persons your company authorizes. You can do this by using the SET LOCKOUT CODE feature in the Programmer. The
Lockout Code restricts any unauthorized panel programming.
After resetting the panel and entering the code 6653, the keypad displays PROGRAMMER. Press COMMAND to
advance through the programming sections until SET LOCKOUT CODE displays (after STOP). Press any top row Select
key. The keypad displays ENTER CODE: – . Enter a 3 to 5 digit Programmer Lockout Code and press COMMAND. The
keypad displays ENTER AGAIN followed by ENTER CODE: –. Enter the same 3 to 5 digit code a second time and press
COMMAND. The keypad displays CODE CHANGED.
Note: The panel does not accept a 5-digit Lockout Code higher than 65535.
Before accessing programmer functions enter the new code number. Write the Lockout Code number down and
keep it in a secure place with access limited to authorized persons only. Lost Lockout Codes require the panel to be
sent back to DMP for repair. You may cancel a Lockout Code by entering 00000 at the Set Lockout Code command.
1.6 Reset Timeout
The panel has a feature that requires you to enter the Programmer within 30 minutes of resetting the panel. After
30 minutes, if you attempt to program by entering the 6653 (PROG) code, the keypad displays: RESET PANEL. You
must reset the panel and enter the program code then begin programming within the next 30 minutes.
If you are already in the Programmer and do not press any keys on the programming keypad for 30 minutes, the
panel terminates programming. All data entered up to that time is not saved unless you run the Stop routine.
Note: Use the Stop routine to exit panel Programming. Ensure the keypad displays “SAVING PROGRAM” to save all
programming changes entered.
1.7 Power Up
When the panel is powered up after an AC power failure, any zone transitions are not recognized for 60 seconds.
Normal zone processing resumes at the end of the 60 seconds.
Vedere la pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 77 78

Commenti su questo manuale

Nessun commento