XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
61
APPENDIX
Always make sure that at least one administrator in your system has a prole with all authorities and areas.
First Access/Second Access - Each prole may be assigned two schedules to allow or restrict access and disarming times.
22.9 UserProlesRecord
This User Proles Record can be used as a tool when programming Devices, Proles, Areas, and Output Groups. Because
these programming options are interrelated, use this sheet to plan the system before you begin the installation and
programming process.
Prole #
Prole
Name
Arm/Disarm
Areas
Access Areas
Output Groups
Arm
Disarm
Alarm Silence
Sensor Reset
Lockdown
Door Lock/Unlock
Door Access
Armed Area
Outputs On/Off
Zone Status
Bypass Zones
Zone Monitor
System Status
System Test
User Proles
User Codes
Extend Schedules
Schedules
Time
Display Events
Service Request
Fire Drill
Temp User Code
Anti-passback
First Access, 1-99
Second Access, 1-99
Third Access, 1-99
Fourth Access, 1-99
Fifth Access, 1-99
Sixth Access, 1-99
Seventh Access, 1-99
Eighth Access, 1-99
Re Arm Delay
Easy Arm/Disarm
Card Plus Pin
Sec Language
22.10 WirelessCheck-inandSupervisionDenitions
DMP 1100 Series Supervision Time Explained
The supervision time programmed for DMP 1100 Series wireless is the number of minutes that must elapse
before a transmitter missing message is generated for a transmitter that is not sending its automatically
generated supervision message. The supervision time is programmable to 3, 60, 240 minutes. Selecting 0
(zero) disables supervision time.
22.11 Keypad Bus and LX-Bus Zone Type Descriptions
This section describes applications for the default Keypad and LX-Bus zone types in Zone Information
programming.
-- (Blank Zone)
Customizable zone type. By default, no actions are programmed to occur with Blank Zone. A zone name must
be entered to use this zone type: This zone type is not the same as an *UNUSED* zone.
NT (Night Zone)
Controlled instant zone used for perimeter doors and windows and interior devices such as PIRs and
Glassbreak detectors.
DY (Day zone)
Used for emergency doors or re doors to sound the keypad buzzer and display the zone name when the zone
is faulted. Day zones also send alarm reports to the receiver during the system armed periods.
EX (Exit zone)
Initiates the entry delay timer when its assigned area is fully armed. Also, can initiate an exit delay timer to
allow a user to exit an area after the arming process starts.