XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
33
OUTPUT INFORMATION
Output Information
12.1 Output Information
This section allows you to program wireless outputs and name wired outputs.
12.2 Output Number
Enter an output number. Entry range is 1 to 6, 450 to 474, 480 to 499, 500 to 999.
In order for wireless output troubles to display at a keypad, the keypad address must be
specied at the Auxiliary 1 Zones option in the Status List programming.
12.3 Output Name
This section allows you to dene a 32 character alphanumeric name for any output
numbers. The name can display on the keypad when a user performs the browser feature at
Outputs On/Off. See the XR150/XR350/XR550 User’s Guide (LT-1278) Appendix for browser
operation.
12.4 Output Real-Time Status
Selecting YES allows Real-Time Status reports of a hardwire device, such as Output ON,
OFF, PULSE, or TEMPORAL to be sent using PC Log reports. Selecting NO disables Real-Time
Status for this output device. Default is NO.
12.5 Serial Number
This option and the next option only display when the output number entered is for a
wireless output. Enter the eight-digit serial number found on the wireless device.
This message displays when the serial number is already programmed for another output.
The programmed output number displays.
12.6 Supervision Time
Press any top row key to select the supervision time required for the wireless output. Press
COMMAND to accept the default time. Default is 240 minutes.
Select the required number of minutes. The transmitter must check in at least once
during this time or a missing condition is indicated for that zone. 1100 Series transmitters
automatically check in based on the supervision time selected for the wireless zone, no
additional programming is needed. Zero (0) indicates an unsupervised transmitter.
The 3 minute supervision time is only available if using an 1135 Wireless Siren.
Note: When the panel is reset, a receiver is installed or powered down and powered up, or
programming is complete, the supervision timer restarts for all wireless outputs.
12.7 Trip with Panel Bell Option
This option displays when the wireless device is an 1135 wireless siren. Select YES to have
the 1135 wireless siren follow the panel’s bell output cadence for the zone type and bell
cutoff time up to 15 minutes. Default is YES.
OUTPUT INFO
OUTPUT NO. X X X
OUTPUT NAME
OUTPUT REAL-TIME
STATUS
NO YES
SERIAL#: XXXXXXXX
ALREADY IN USE
OUTPUT NO: XXX
SUPRVSN TIME: 240
0 3 60 240
TRIP WITH PANEL
BELL NO YES