XR150/XR350/XR550 Series Programming Guide Digital Monitoring Products
49
ZONE INFORMATION
Note: When more areas are selected at Arm/Disarm Areas than are authorized in the
User Prole, in the future the user can be given access authority to additional areas
through the User Prole without requiring additional panel programming to select Arm/
Disarm Areas. See User Proles in the Appendix or refer to the XR150/XR350/XR550
Series User’s Guide (LT-1278).
In an All/Perimeter or Home/Sleep/Away system, this species the area to be armed by
the Key Fob button being programmed. For All/Perimeter systems, choose PERIM or ALL,
for Home/Sleep/Away or Home/Away systems, choose HOME, SLEEP, or AWAY.
Note: Areas 3 and higher in an All/Perimeter system, and areas 4 and higher in a Home/
Sleep/Away system are not available for use.
After selecting the areas, for one-button key fobs the Zone No.: option displays. For
two-button or four-button key fobs, the Key Fob Button Selection option displays to
program additional buttons.
18.11.10 Output Number
You can specify any relay output/Favorite to operate when OUT (Output), PN (Panic),
PN2 (Panic 2), EM (Emergency), or EM2 (Emergency 2) is selected for a key fob Button
Action and the button is pressed. Valid range is 1 to 6, 500 to 999,
D1 to D16, F1 to F20, or G1 to G20. For an output turned on by a PN, PN2, EM, or EM2
button action, the output turns off when any area is disarmed.
To enter an output/Favorite number, press a top row Select key followed by the output/
Favorite number. Press the COMMAND key.
18.11.11 Output Action
This option allows you to dene the output action (STD, PLS, MOM, TGL, OFF) for the
selected output number. The default is Steady.
yyy = the name of the button being programmed (TOP, BTM, LFT, RGT).
xxxxxxxx = the currently dened output action.
STD (Steady) - The output is turned on and remains on.
PLS (Pulse) - The output alternates one second on and one second off.
The pulsing rate for a Model 716 relay attached to the LX-Bus is 1.6 seconds.
Note: Pulse is not available for key fob button output programmed D1 to D16 or G1 to
G20.
MOM (Momentary) - The output is turned on only once for one second.
TGL (Toggle) - The output alternates between the on state and off state. Each button
press toggles the output state.
Note: Toggle is not available for key fob button output programmed G1 to G20.
OFF (Off) - The output is turned off. If programmed, the output was turned on by some
other means such as another button press, a zone action, or a schedule.
Note: When the output is assigned to PN/PN2 or EM/EM2 button action and is turned
on, the output turns off when any area is disarmed.
When the output action is steady, pulse or toggle and the output is turned on, the
output remains on until:
— the output cutoff time expires
— the output is reset from the keypad menu
— toggled off
18.11.12 Next Zone
Select YES to return to the ZONE NO: - option to program a new zone. Select NO to
display the Alarm Action option.
Note: All wireless programming is stored in the panel. The 1100X Wireless Receiver
obtains the necessary programming information from the panel each time the receiver
powers up, when the programmer STOP routine is selected or the panel is reset. The
receiver memory refresh takes up to 10 seconds to complete depending on the number
of wireless zones programmed and the Red LED remains on during this time. Normal
receiver operation is inhibited during the memory refresh period.
You must also make these selections for the Disarmed Short, Armed Open, and Armed
Short zone conditions. Press COMMAND to continue.
ARM AREAS: PERIM
OUTPUT NO: XXX
OUTPUT ACTION:
yyy: XXXXXXXX
OUTPUT ACTION?
STD PLS MOM TGL
OUTPUT ACTION?
OFF
NEXT ZONE NO YES