XRSuper6/XR20/XR40 Programming Guide Digital Monitoring Products
9
CommuniCaTion
3.9
TEST TIME
00:00 AM PM
Test Time
Press COMMAND to enter the Test Time. Enter the time of day the panel sends the
test report to the SCS-1R Receiver. Use entries between 12:00 to 11:59 and then
choose AM or PM.
Automatic test messages are sent through the dialer unless NET is programmed as
Main Communication and no telephone numbers have been programmed. Then the
test message is sent through the network.
3.10
RECEIVER 1 PROG
Receiver 1 Programming
Allows you to set the options for the rst receiver the XRSuper6/XR20/XR40 panel
attempts to contact when sending reports. The XRSuper6/XR20/XR40 supports
communication to two receivers.
3.11
ALARM NO YES
Alarm Reports
YES enables Abort, Alarm, Alarm Restoral, Alarm Bell Silenced, Ambush, Exit Error,
and System Recently Armed reports to be sent to this receiver.
3.12
SPV/TRBL NO YES
Supervisory/Trouble Reports
YES enables Supervisory, Trouble, Trouble Restoral, Force Armed, Late to Close, and
Fault reports to be sent to the receiver.
3.13
O/C USER NO YES
Opening/Closing and User Reports
YES enables Opening/Closing, Door Access, Schedule and Code Changes, Bypass, and
Sensor Reset reports by user to be sent to this receiver.
3.14
TEST RPT NO YES
Test Report
Enter YES to enable the Recall Test report to be sent to this receiver.
3.15
BACKUP NO YES
Backup Reporting
YES enables this receiver to be a backup to the other receiver in the event the
other receiver cannot be contacted.
Note: When Backup Reporting is set to YES, the Cellular Backup Output programmed
in Output Options is automatically set to zero.
3.16
-
-
FIRST PHONE NO.
First Telephone Number
Enter the rst number the panel dials to send reports to this receiver. A phone
number may contain two lines of 16 characters to equal 32 characters. You can
program a three-second pause in the dial ing se quence by en tering P. Program a
dial tone detect by entering D. These characters are counted as part of the 32
characters.
Call Waiting: You can place the “* 7 0 P” (Star, Seven, Zero, Pause) in the telephone
number rst position to cancel Call Waiting. For example, program NET with second
line DD and phone number *70P555-1212, and you have NET with Call Waiting
cancelled on the second line.
Caution: A call waiting cancel programmed on a non-call waiting telephone
line would prevent communication to the central station.
3.17
-
-
SECOND PHONE NO.
Second Telephone Number
The panel dials the second number after two successive attempts failed using the
rst number. If the panel cannot reach the receiver after two attempts using the
second number, it returns to the rst number and makes two additional attempts. A
total of ten dialing attempts are made using the rst and second phone num bers. If
a second phone number is not entered, the rst phone number is used for all dialing
attempts. Each number can be up two lines of 16 characters to equal 32 characters
in length, in cluding any P, D, or *70P char acters entered for pause, dial tone detect,
or call waiting cancel option.
Vedere la pagina 16