Digital Monitoring Products XRSuper6/XR20/XR40 Programming Guide
40
aPPendiX
The third column from the left is the second digit of the 2-digit event code sent to the receiver. The
fourth column (on the right) is what that character represents. See below:
1st
Digit
1st Digit
Description
2nd Digit 2nd Digit Description
1 Fire Alarm 1 to A, B, D Zones 1 to 10 (1 to A), Keypad Fire Buttons (B), and Zones greater than 10 (D)
4-2 Communication Reports
The table below is a complete list of the hexadecimal characters sent using the DMP 4-2 communication
format.
1st
Digit
1st Digit Description 2nd Digit 2nd Digit Description
1 Fire Alarm 1 to A, B, D Zones 1 to 10, Keypad Fire Buttons, and Zones greater than 10
2 Panic Alarm 1 to A, B, D Zones 1 to 10, Ambush, and Zones greater than 10
3 Burglary Alarm 1 to A, B, D Zones 1 to 10, Keypad Police Buttons, and Zones greater than 10
4 Emergency Alarm 1 to A, B, D Zones 1 to 10, Keypad Emergency Buttons, and Zones greater
than 10
5 Supervisory Alarm 1 to A, D Zones 1 to 10, and Zones greater than 10
6 Aux 1, Aux 2, or Blank Type Alarms 1 to A, D Zones 1 to 10, and Zones greater than 10
7 System Report 1 Automatic Recall
7 System Report 2 Non-AlarmOverow
7 System Report 3 ZoneAlarmOverow
7 System Report 4 System Test
7 System Report 5 Unsuccessful Remote Connect
7 System Report 6 System Recently Armed
7 System Report 7 Exit Error
7 System Report 8 Remote Programming Complete
7 System Report 9 Local Programming
7 System Report A Transmit Fail
7 System Report B System Not Armed by Scheduled Time
7 System Report E Bell Circuit Trouble
7 System Report F Bell Circuit Restored
8 User Code Addition 1 to C, D, F Users 1 to 12, 0, and Users greater than 12
8 User Code Deletion 1 to C, D, F Users 1 to 12, 0, and Users greater than 12
8 User Code Change 1 to C, D, F Users 1 to 12, 0, and Users greater than 12
A Zone Bypass or Force Arm 1 to A, D Zones 1 to 10, and Zones greater than 10
B Disarming 1 to C, D, F Users 1 to 12, 0, and Users greater than 12
C Arming 1 to C, D, F Users 1 to 12, 0, and Users greater than 12
D Abort Received 1 None
E Any Zone Restoral, Reset, or System
Restoral
1 to A, B, C, D Zones 1 to 10, Battery, AC, and Zones greater than 10
F Zone Trouble, Fault, Transmitter Low
Battery or Missing, or System Trouble
1 to A, B, C, D Zones 1 to 10, Battery, AC, and Zones greater than 10
4-2 Examples
The following examples are the actual event codes a central station would receive. The full report would
also include the account number and checksum.
When the central station receives this event code It means
1A A Fire alarm is being reported on zone ten
2B An Ambush alarm is being reported
FB A battery trouble is being reported
F9 A Trouble is being reported on zone nine
1st digit of event code
sent to the receiver
Describes the event 2nd digit of event code
sent to the receiver
Denestheusernumber,zonenumber,orother
information about the event
Commenti su questo manuale