14.12 Common Keypad Messages
Message Meaning Possible Solutions
INVALID CODE
The user code you have entered is not
recognized by the system.
Check the user code and try again.
CLOSING TIME
(XR20/XR40 Only)
The schedule has expired but the system has
not been armed.
Users still on the premise should arm the system or
extend the schedule to a later time.
AC TROUBLE The system is not getting proper power. Check that the AC connections are good.
BATTERY
TROUBLE
The battery is either low or missing.
Check that the battery connections are good and
the battery is still good.
SYSTEM TROUBLE
or
SERVICE
REQUIRED
There is a problem with one or more
components in the system.
MakesuretheJ16jumperisremovedfromthe
panel. Make sure there is not a short or open
condition on the green data wire to the keypad.
You may also need to check that all of the keypads
and expansion modules on the bus are good.
SYSTEM BUSY
The system is performing another task with a
higher priority.
Wait a few moments for the system to complete the
task.MakesuretheJ16jumperisnotonthepanel.
If the message displays for a long period of time,
the processor could be locked up.
NON-POLLED
ADDRESS
(770 Keypad only)
Remote programming is in progress or the
keypad address is not programmed correctly.
Adjustkeypadaddresstotheappropriatenumber
for the panel type.
TRANSMIT FAIL
The panel has attempted to communicate
with the central station 10 times and has not
succeeded.
Verify your communication type, account number,
and phone number. Make sure the telephone line is
connected and working properly.
ENTER CODE
(When entering
Programming)
A lockout code has been programmed for the
panel.
Enter the lockout code.
WIRELESS
TROUBLE
The panel is unable to communicate with the
wireless receiver.
Verify the receiver is properly connected to the panel.
Verify the correct House Code is programmed in
System Options.
The wireless receiver is missing.
Listings and Approvals
ANSI/SIA CP-01-2000 False Alarm Reduction
California State Fire Marshal (CSFM)
FCC Part 15
FCC Part 68 Registration ID CCKUSA-18660-AL-R
Underwriters Laboratories (UL) Listed
ANSI/UL 365 Police Connected Burglar
ANSI/UL 609 Local Burglar
ANSI/UL 1023 Household Burglar
ANSI/UL 1076 Proprietary Burglar
ANSI/UL 1610 Central Station Burglar
ANSI/UL 985 Household Fire Warning
Standard Line Security with Model iCOMSL
Commenti su questo manuale