SySTem oPTionS
6.11
ZN ACTY HOURS:
Zone Activity Hours
This option allows you to monitor a person living alone for non-activity. Enter the
number of hours, 0 to 9, allowed to elapse without a disarmed zone being tripped
before a message is sent to the receiver. Default is 0 (zero). When the system is
disarmed, the timer begins to countdown the number of hours programmed. Each
time activity occurs, the timer restarts the countdown.
Before the countdown time expires, the keypad sounds a tone and PRESS ANY KEY
displays to allow the user to restart the activity timer. The duration of the tone is
the number of seconds programmed for Entry Delay 2.
Select the SUPV/TRBL receiver option in Receiver 1 or 2 programming to send S93
ALARM: User Activity Not Detected, S94 Alert: Activity Check Enabled, and S95 Alert:
Activity Check Disabled messages.
When an open/close schedule is programmed, the timer only counts down during
the scheduled open period. Also, when a schedule is programmed, if the timer is
counting down and the scheduled open time occurs, the timer resets and begins the
countdown again.
6.12
ARM ACTY DAYS:
Arm Activity Days
This allows you to select the number of days a countdown timer is set for area
arming and disarming activity. The range for the countdown timer is 00 to 99.
When the timer counts down to zero because of no area arming or disarming
activity, the panel sends a “No Arming/Disarming” message to the receiver at 10:
00 AM. Each time an area is armed or disarmed, the timer is restarted. When the
countdown timer expires because of no area arming or disarming activity, and a
message is sent, the timer does not restart until a panel reset occurs or an area is
armed or disarmed.
The SUPV/TRBL receiver option must be selected in Receiver 1 or 2 programming
for the message to be sent.
6.13
TIME CHG NO YES
Time Zone Changes
This option allows the panel to request automatic time changes from the DMP
SCS-1/SCS-1R Receiver. For the receiver to send time changes, it must be
programmed to send time changes and must be receiving time change updates from
the host automation computer at least every 24 hours. Default is YES.
HRS FROM GMT: 6
When time zone is programmed YES, enter the number (0-23) that indicates the
Greenwich Time zone (GMT) where the panel is located. The default is 6. See table
below for GMT values.
GMT
City/Time Zone GMT City/Time Zone
0
London, Monrovia, Lisbon, Dublin, Casablanca, Edinburgh 13 New Cadelonia
1
Cape Verde Island, Azores 14 Guam, Sydney
2
Mid-Atlantic, Fernando de Noronha 15 Tokyo, Seoul
3
Buenos Aires, Georgetown, Brasilia, Rio de Janeiro 16 Hong Kong, Singapore
4
Atlantic Time (Canada), Caracas, La Paz, Santiago 17 Bangkok, Hanoi
5
Eastern Time (US, Canada) Bogota, Lima, Arequipa 18 Dhaka, Almaty
6
Central Time (US, Canada), Mexico City, Saskatchewan 19 Islamabad, Karachi
7
Mountain Time (US, Canada), Edmonton 20 Abu Dhabi, Kazan
8
PacicTime(US,Canada),Tijuana 21 Moscow, Bagdad
9
Alaska 22 Eastern Europe
10
Hawaii 23 Rome, Paris, Berlin
11
Midway Island, Samoa
12
Fiji,MarshallIsland,Wellington,Auckland,Kwajalein,Kamchatka
6.14
TIME DISP NO YES
Time Display
YES allows the keypad to display the time and day in the Status List. When NO is
selected, time and day of the week are not displayed.