XRSuper6/XR20/XR40 Programming Guide
Digital Monitoring Products www.dmpnet.com 2500 N. Partnership Boulevard Springfield, MO 65803
3.1 COMMUNICATION
The Communication section allows you to configure the communication settings for
the XRSuper6/XR20/XR40 panel. After choosing the Communication Type, continue
through the list of options.
3.2 COMMUNICATION TYPE
This specifies the communication method the panel uses to contact the receiver.
Press any Select key to display the following communication options:
NONE - For local systems. Selecting this ends communication programming.
DD - Digital Dialer communication to DMP SCS-1 Receivers.
4-2 - 4-2 communication to non-DMP receivers.
M2E - Modem IIe communication to non-DMP receivers. This format sends the report
codes of the Radionics Modem IIe communication format.
CID - Contact ID communication to non-DMP receivers. This format sends the report
codes of the Ademco Contact ID communication format.
3.3 ACCOUNT NUMBER
Enter the account number sent to the receiver.
DD - The range of account numbers for Digital Dialer is 1 to 65535. For account
numbers of four digits or less, you do not have to enter leading zeros. The panel
automatically right justifies the account number.
4-2, M2E, and CID - The range of account numbers for these formats is 1 to 9999.
3.4 TRANSMIT DELAY
Enter the length of time the panel waits before sending burglary alarm reports to
the receiver. The available range is 10 to 60 seconds in ten-second increments.
Alarm bells and relay outputs are not delayed during this period. Burglary Outputs
must be programmed for Steady.
If the area where the alarm occurred is disarmed during the Transmit Delay, only an
Abort Report is sent. Abort Reports must be set to YES. Enter zero to disable
Transmit Delay.
3.5 DTMF
YES enables tone dialing. NO enables rotary dialing.
3.6 DEFER TEST TIME
Select YES to allow the programmed test report to be deferred if the panel
communicates with a receiver within the time set in Test Frequency. Select NO to
send the test report as programmed in Test Frequency regardless of previous panel
communication.