25
XRSuper6/XR20/XR40 Programming Guide
2500 N. Partnership Boulevard Springfield, MO 65803 www.dmpnet.com Digital Monitoring Products
9.9C OUTPUT ACTION
Entering an Output Number displays this prompt that allows you to assign an output
action to the relay. A description of the available output actions is given below:
STEADY - The output is turned on and remains on until the area is disarmed, an
output cutoff time expires, or the output is reset from the keypad User Menu.
PULSE - The output alternates one second on and one second off until the area is
disarmed, an output cutoff time expires, or the output is reset from the keypad User
Menu.
MOMENTARY - The output is turned on only once for one second.
FOLLOW - The output is turned on and remains on while the zone is in an off normal,
or bad condition. When the zone restores, the output is turned off.
After you have made the three selections in sections 9.9A through 9.9C, the display
prompts you for the same three selections for Disarmed Short, Armed Open, and
Armed Short conditions. If the zone is a 24-hour type, only the Armed Open and
Armed Short conditions are displayed. When you have programmed all of the zone
conditions, the Swinger Bypass selection is then displayed.
9.10 SWINGER BYPASS
YES allows the zone to be bypassed by the panel after four alarm, trouble, or local
trips within one to two hours. Selecting NO disables swinger bypassing for this zone.
After the first trip, if the zone does not trip 3 more times before the remaining time
expires, the bypass trip counter returns to zero and the zone must trip a full 4 times
within the next hour to be automatically bypassed.
A report of a swinger bypass is sent to the receiver if Bypass Reports has been
enabled. See the Bypass Reports section.
Bypassed zones are automatically reset when the area they are assigned to is
disarmed. All bypassed 24-hour zones are reset when the system is disarmed.
9.11 PREWARN ADDRESS (XR40 only)
At the start of the entry delay, all keypad addresses selected here display ENTER
CODE:-. If you want the prewarn to sound at all eight addresses, leave the default
as shown.
To delete an address, press the matching number on the keypad. To disable
prewarning at all keypads, press a top row key to clear the addresses shown. Press
the COMMAND key when the address selection is complete.
9.12 ENTRY DELAY
Select the entry delay timer for this zone. Entry delay timers 1 and 2 are
programmed in Entry Delay in the System Options menu.
ZONE INFORMATION
ENTRY DELAY: 1
SWGR BYP YES
PREWARN: 12345678
ACTION:
STD PLS MOM FOLW