XRSuper6/XR20/XR40 Programming Guide
Digital Monitoring Products www.dmpnet.com 2500 N. Partnership Boulevard Springfield, MO 65803
1.3 Programming Menu
You are now ready to start programming the XRSuper6/XR20/XR40 panel. Pressing the COMMAND key
scrolls you through the 10 programming menu items listed in below.
Note: The 692 Security Command keypad is not suitable for panel programming.
Menu Item Section in this manual
Initialization 2
Communication 3
Remote Options 4
System Reports 5
System Options 6
Output Options 7
Area Information 8
Zone Information 9
Stop 10
Set Lockout Code 11
To select a section for programming, press any one of the top row Select keys when the name of that
section is displayed on the keypad. The detailed instructions for each programming step are found in
sections 2 to 11 of this manual.
1.4 Programmer Lockout Codes
Although the XRSuper6/XR20/XR40 panel allows you to enter the built-in Programmer without a lockout
code, we recommend you install one to restrict programming access to only those persons your
company authorizes. You can do this by using SET LOCKOUT CODE at the end of the programming
menu.
Installing a lockout code
1. After entering the Programmer menu, the keypad displays PROGRAMMER. Press the COMMAND
key until SET LOCKOUT CODE is displayed (after STOP).
2. Press any top row Select key. At the ENTER CODE: - display, enter a 1- to 5-digit programmer
lockout code. Press COMMAND.
3. The displays shows ENTER AGAIN. Enter the same lockout code again and press COMMAND. The
display shows CODE CHANGED. The new code number must now be entered before the
Programmer menu can be accessed.
The lockout code number should be written down and kept in a secure place with access limited to
authorized persons only.
Lost Lockout Code requires factory reset: If you lose or forget the lockout code, the panel must be
sent back to the factory to be reset. There is no field option for gaining access to the panel without a
valid lockout code.
1.5 Reset Timeout
The XRSuper6/XR20/XR40 has a feature that requires you to enter the Programmer within 30 minutes of
resetting the panel. After 30 minutes, if you attempt to program by entering the 6653 (PROG) code,
the keypad displays: RESET PANEL. You must reset the panel and enter the program code within the
next 30 minutes.
If you are already in the Programmer and do not press any keys on the programming keypad for 30
minutes, the panel terminates programming. All data entered up to that point is saved in the panel's
memory.
Using the STOP function disarms all areas: To exit the panel's Programmer you must use the Stop
function. The STOP option is the second to the last option in programming. The Stop function disarms
all areas and clears the panel's Status List.
The programming session is then terminated and the keypad returns to the Status List.