Digital Monitoring Products XTL/XTLC Programming Guide
8
COMMUNICATION
3.24 Test Report
YES enables the Recall Test report to be sent to this receiver. Default is NO.
3.25 First IP Address
Enter the rst (primary) IP address where the panel sends cell messages. Enter all
12 digits and leave out the periods. For example, enter IP address 192.168.0.250 as
192168000250. The periods display automatically.
The message is sent using rst GPRS APN and the rst IP Address. If no acknowledgment
is received, rst GPRS APN and the second IP address are used, followed, if needed, by
second GPRS APN and rst and second IP addresses, respectively.
3.26 First IP Port
Enter the rst IP port number to be used in conjunction with the First IP Address. The
IP port identies the port used to communicate messages to and from the panel. The
default IP Port setting is 2001.
3.27 Second IP Address
Enter the second IP address where the panel sends cell messages. Enter all 12 digits and
leave out the periods. For example, enter IP address 192.168.0.250 as 192168000250.
The periods display automatically.
3.28 Second IP Port
Enter the second IP port number to be used in conjunction with the second IP Address.
The IP port identies the port used to communicate messages to and from the panel.
The default IP Port setting is 2001.
TEST RPT NO YES
FIRST IP ADDR
000.000.000.000
FIRST IP PORT
2001
SECOND IP ADDR
000.000.000.000
SECOND IP PORT
2001