Digital Monitoring Products XTL Series Guida di Installazione Pagina 20

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 49
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 19
XTL/XTLC Programming Guide Digital Monitoring Products
13
SYSTEM REPORTS
System Reports
7.1 System Reports
This function allows you to select the reports the XTL/XTLC sends to the receiver.
7.2 Opening/Closing Reports
NO - No Opening/Closing Reports are sent.
YES - Sends Opening/Closing Reports for each programmed area.
7.3 Abort Reports
YES allows the panel to send an Alarm Abort Report to the receiver any time an area is
disarmed during Transmit Delay before an alarm report is sent and the Bell Cutoff Time
has not expired. See the Bell Cutoff section. The area must be disarmed and no zones
that were in alarm can still be armed.
YES also allows a Bell Silenced Report to be sent if the alarm bell is silenced with a valid
user code during an alarm. Default is NO.
Note: Alarm Cancel or Verify Reports are sent if the alarm is canceled or veried after
being sent to the alarm receiver, if the Bell Cutoff timer has not expired. The Abort
Reports option does not affect Cancel or Verify reports.
The panel will not send Abort reports for Fire zones, or Supervisory-type zones.
7.4 Zone Restoral Reports
This option allows you to specify whether the panel sends zone restoral reports and
when they will be sent.
NO - Restoral reports are not sent by the panel.
YES - The panel always sends zone restoral reports at the time the zone restores from
an alarm or trouble condition.
DISARM - The panel sends zone restoral reports when a zone that has restored from an
alarm or trouble is disarmed. Twenty-four hour zones send restorals immediately.
7.5 Bypass Reports
YES allows the panel to send all zone bypass, reset, and force arm reports to the
receiver. The bypass report includes the zone number, zone name, and the user number
of the individual bypassing the zone.
7.6 Code Change Reports
YES allows the panel to send all code additions, changes, and deletions to the receiver.
The code change report includes the user number added or deleted and the user number
of the individual making the change.
7.7 Ambush
YES allows an ambush report to be sent any time user code number one is entered at a
keypad. Selecting NO disables the ambush report and allows user code number one to
operate the same as all other codes.
7.8 Late To Open
Enter 1-240 as the number of minutes to elapse that the system may remain armed after
the opening time of a schedule without sending a Late To Open message. If the system
continues to be armed after the Late to Open minutes expire, a Late To Open message is
sent to the central station. Default is 0, which disables the Late To Open option.
7.9 Early To Close
Enter 1-240 as the number of minutes that the system can be armed prior to the
scheduled closing time. If the system is armed prior to the Early to Close minutes, an
Early To Close message is sent to the central station. Default is 0, which disables the
Early to Close option.
SYSTEM REPORTS
O/C RPTS NO
NO YES
ABORT NO YES
RESTORAL YES
NO YES DISARM
BYPASS NO YES
CODE CHG NO YES
AMBUSH NO YES
LATE TO OPEN
EARLY TO CLOSE
Vedere la pagina 19
1 2 ... 15 16 17 18 19 20 21 22 23 24 25 ... 48 49

Commenti su questo manuale

Nessun commento